Product categories: Burning biomass boiler
Product keywords:coal-fired boiler, steam boiler, coal-fired hot water boiler, vertical coal-fired boiler
Introduction:Coal-fired boilers, steam boilers, gas boilers, electric boilers, hot water boilers_Compact structure, easy installation and relocation, small footprint, low capital investment. Combining high-temperature coal seam with water vapor, the chemical reaction fully occurs to produce combustible gas for environmentally friendly combustion. combustible gas ...
Telephone:+8613526427771
Southeast Asia sales calls:+66890892025
Vertical coal-fired steam boiler production area

Vertical coal-fired steam boiler and desulfurization and dust removal equipment (Yufa, Beijing)

Vertical coal-fired steam boiler production area

Vertical coal-fired steam boiler production workshop

Vertical coal gasification environmental protection boiler

1. Compact structure, convenient installation and relocation, small footprint and low infrastructure investment.
2. Combining the high-temperature coal seam with water vapor, the chemical reaction fully occurs to produce combustible gas for environmentally friendly combustion.
3. After the combustible gas is fully burned, the original emission concentration of smoke and dust is low, dust-free and sulfur-free, which is a new type of green environmental protection product.
4. The flue gas washes the convection tube bundle through forced rotation, with multiple returns and multiple cycles, making full use of the heating surface and waste heat to improve thermal efficiency.
5. Mixed double combustion of anthracite and gas, high efficiency, energy saving and environmental protection, suitable for cities and regions with high environmental protection requirements.
6. The water-sealed slag removal method of combustion can ensure the sealing of the gas and effectively reduce the spread of dust, making the boiler room clean.
7. Combustion with gas, saving more than 15% than ordinary layer combustion.
8. It leaves the factory in the form of quick assembly, and after being transported to the site, it can be operated by splicing valves, water sources, pipelines, etc.

Operation essentials
Requirements for softened water
1. Ensure the normal power supply of softened water. Under normal circumstances, the power supply of softened water is not allowed to be disconnected.
2. Ensure the concentration of salt in the salt box and observe the amount of salt used. (Use industrial salt, prohibit the use of iodized salt) and observe the salt absorption, sewage discharge, backwashing and regeneration of the softening equipment, and make records.
3. The valve before the valve of the softened water supply system is not allowed to be closed to ensure that there is a normal supply of water between the tap water and the softener, so as not to affect the regeneration of softened water and ensure the quality of boiler feed water. As the water in the softened water tank is full, when the water source needs to be turned off, the valve behind the softened water can be closed, that is, the valve is closed in front of the softened water tank.
4. The adjustment wheel on the softened water is already in a normal state and does not need to be operated every day. It should be rotated clockwise during operation. Reversal is prohibited, and curious rotation should be avoided.
Boiler operation essentials
1. Before each fire, first check whether the valve between the boiler and the sub-cylinder is open normally, and whether the screws are loose. If any problems are found, they should be repaired in time. question.
2. When starting a fire, first observe the boiler water level to ensure that the boiler water level is in a normal state before raising the fire and opening the damper. After observing that the boiler pressure is close to the operating pressure, properly control the firepower, within the safe pressure, try to avoid the overpressure opening of the safety valve, which will not only waste fuel but also bring pressure fluctuations to production and affect the production plan.
3. The flame control can be controlled according to the chimney damper and the furnace door at the same time. When the pressure is increased normally, the chimney damper is opened and the furnace door is closed, so that the air volume can enter the furnace through the grate. If the pressure is close to the upper line pressure, you can properly close the damper or open the furnace door to control the pressure. Water is not allowed for emergency fire extinguishing.
4. Regarding the water level control system, first of all, the water level control system cannot be completely relied on. The specific water level should be subject to the observation of the fireman. clear.